Background: Biomechanical measurement tools have been developed and widely used to precisely quantify knee anterior-posterior laxity after anterior cruciate ligament (ACL) injury. However, validated objective device to document knee rotational laxity, though being developed by different researchers, are not yet widely used in the daily clinical practice. A new biomechanical device was developed to quantify knee internal and external rotations. Methods: The reliability of the new biomechanical device which measures knee rotations were tested. Different torques (1-10Nm) were applied by the device to internally and externally rotate human cadaveric knees, which were held in a flexion angle of 30 . The rotations were measured by the device in degrees. There were two independent testers, and each tester carried out three trials. Intra-rater and inter-rater reliability were quantified in terms of intraclass correlation (ICC) coefficient among trials and between testers. The device was verified by the comparison with a computer assisted navigation system. ICC was measured. Mean, standard deviation and 95% confident interval of the difference as well as the root mean square difference were calculated. The correlations were deemed to be reliable if the ICC was above 0.75. Results: The intra-rater and inter-rater reliability achieved high correlation for both internal and external rotation, ranged from 0.959 to 0.992. ICC between the proposed meter and the navigation system for both internal and external rotation was 0.78. The mean differences were 2.3 and 2.5 for internal and external rotation respectively. Conclusions: A new knee rotational laxity meter was proposed in this study. Its reliability was verified by showing high correlation among trials. It also showed good correlation to a gold standard of measurement. It might be used to document knee rotational laxity for various purposes, especially after ACL injury, after further validation of the device in human subjects

Funding

This research project was made possible by equipment/resources donated by The Hong Kong Jockey Club Charities Trust and supported by Innovation and Technology Fund (ITS/039/09, InP/ 277/09, InP/313/09), The Government of the Hong Kong Special Administrative Region.

History

School

  • Sport, Exercise and Health Sciences

Published in

Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology

Citation

LEE, J. C-Y. ... et al., 2018. A non-invasive biomechanical device to quantify knee rotational laxity: Verification of the device in human cadaveric specimens. Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology, 16, pp.19-23.

Publisher

© 2018 Asia Pacific Knee, Arthroscopy and Sports Medicine Society. Published by Elsevier BV

Version

  • VoR (Version of Record)

Publisher statement

This work is made available according to the conditions of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) licence. Full details of this licence are available at: https://creativecommons.org/licenses/by-nc-nd/4.0/

Publication date

2018

Notes

This is an Open Access Article. It is published by Elsevier under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) licence. Full details of this licence are available at: https://creativecommons.org/licenses/by-nc-nd/4.0/

ISSN

2214-6873

Language

  • en

Usage metrics

    Loughborough Publications

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC