Title: A compact electric potential sensor array for the acquisition and reconstruction of the 7-lead electrocardiogram without electrical charge contact with the skin
Authors: Harland, C.J.
Clark, T.D.
Peters, N.S.
Everitt, Mark J.
Stiffell, P.B.
Keywords: Electrocardiogram
Electric potential sensor
Cardiac sensor array
Issue Date: 2005
Publisher: © IOP Publishing Ltd.
Citation: HARLAND, C.J. ... et al., 2005. A compact electric potential sensor array for the acquisition and reconstruction of the 7-lead electrocardiogram without electrical charge contact with the skin. Physiological Measurement, 26 (6), pp. 939 - 950.
Abstract: Conventional electrocardiogram (ECG) systems make use of separate electrical connections to the arms and legs. These use a ‘long baseline’ for the voltage reference potential which in the case of precordial ECG leads is provided using aWilson central terminal (WCT) wiring configuration. The aims of this project were (a) to construct compact, non-invasive surface ECG sensor arrays which would operate without the need for a WCT reference, (b) to obtain high quality precordial ECGs showing fine differences inECGdetail between small adjacent areas of the chest and (c) to reconstruct, from a compact array of four sensors, ECGs which closelymatch to the conventional 7-lead ECG system, but without the need for multiple wires and long baselines. In this paper, we describe two sensor array configurations which have been constructed using electric potential sensors (EPSs). We show high quality precordial ECGs obtained from small areas of the surface of the chest and show the different angular vectors (leads) in the frontal cardiac plane constructed using signals from the array elements. We suggest that these ECG arrays, which are simple to apply, should prove to be a valuable tool in providing useful information about the state of the heart.
Description: This article was published in the journal, Physiological Measurement [© IOP Publishing Ltd.] and the definitive version is available at: http://dx.doi.org/10.1088/0967-3334/26/6/005
Version: Published
DOI: 10.1088/0967-3334/26/6/005
URI: https://dspace.lboro.ac.uk/2134/12061
Publisher Link: http://dx.doi.org/10.1088/0967-3334/26/6/005
ISSN: 0967-3334
Appears in Collections:Closed Access (Physics)

Files associated with this item:

File Description SizeFormat
0967-3334_26_6_005.pdfPublished version744.28 kBAdobe PDFView/Open

 

SFX Query

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.