Title: Regional microclimate humidity of clothing during light work as a result of the interaction between local sweat production and ventilation
Authors: Ueda, Hiroyuki
Inoue, Yoshimitsu
Matsudaira, Mitsuo
Araki, Tsutomu
Havenith, George
Keywords: Humidity
Clothing
Air
Thermal testing
Issue Date: 2006
Publisher: © Emerald
Citation: UEDA, H. ... et al., 2006. Regional microclimate humidity of clothing during light work as a result of the interaction between local sweat production and ventilation. International Journal of Clothing Science and Technology, 18 (3-4), pp. 225 - 234.
Abstract: Purpose – The aim of this study is to explore the influence of the clothing ventilation in three body regions on the humidity of the local clothing microclimates under five work-shirts immediately after the onset of sweating in light exercise. Design/methodology/approach – The clothing microclimate ventilations were measured at chest, back and upper arm using a manikin. Separate wear trials were performed to determine the sweat production and the humidity of the clothing microclimate at the same locations as where the ventilation was measured during light exercise. Findings – Every shirt shows the greatest value of ventilation index (VI) for the chest and the smallest one for the upper arm. The values of VI differ remarkably at the chest among the five shirts. Comfort sensation became gradually worse as the time passed after starting exercise. There was no significant difference among the clothing conditions in mean values of rectal temperature, local skin temperatures, microclimate temperatures, microclimate relative humidities and local sweat rates at three regions over 10?min after the onset of sweating. A relationship was observed between the ratio of the mean moisture concentration in the clothing microclimate to the mean sweat rate at the chest and the back and the VI. Originality/value – The results suggest that clothing ventilation should be measured in different body regions in response to sweat rates in corresponding regions.
Description: This article was published in the journal, International Journal of Clothing Science and Technology [© Emerald] and the definitive version is available at: http://dx.doi.org/10.1108/09556220610668473
Version: Accepted for publication
DOI: 10.1108/09556220610668473
URI: https://dspace.lboro.ac.uk/2134/12496
Publisher Link: http://dx.doi.org/10.1108/09556220610668473
ISSN: 0955-6222
Appears in Collections:Published Articles (Design School)

Files associated with this item:

File Description SizeFormat
Ueda et al 2006.pdfAccepted version239.33 kBAdobe PDFView/Open

 

SFX Query

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.