Loughborough University
Leicestershire, UK
LE11 3TU
+44 (0)1509 263171
Loughborough University

Loughborough University Institutional Repository

Please use this identifier to cite or link to this item: https://dspace.lboro.ac.uk/2134/13328

Title: Thin film tribology of pharmaceutical elastomeric seals
Authors: Grimble, David W.
Theodossiades, Stephanos
Rahnejat, Homer
Wilby, M.
Keywords: Pressurised metered dose inhaler
Elastomeric pharmaceutical seals
Soft EHL
Issue Date: 2013
Publisher: © Elsevier
Citation: GRIMBLE, D.W. ... et al, 2013. Thin film tribology of pharmaceutical elastomeric seals. Applied Mathematical Modelling, 37 (1-2), pp.406-419.
Abstract: The primary purpose of valve seals in inhalation and other drug dispensing devices is to inhibit leakage of highly volatile formulation from pressurised canisters. This requirement often conflicts with smooth operation of valves because of poor lubrication of seals. The repercussions of this can be variability in dispensed dose as well as loss of prime and gradual wear of seals. Although a good volume of literature is available for general purpose o-ring seals, the characteristic behaviour of those used in pharmaceutical devices deviate from this significantly. The paper studies tribology of such seals, subjected to global fitment and canister pressure deformation and localised conjunctional elastohydrodynamic pressures. It is shown that ideally smooth seals would operate under iso-viscous elastic (soft EHL) regime of lubrication. However, the predicted ultra-thin films are insufficient to ensure fluid film lubrication because of rough micro-scale nature of elastomeric seal surface and poor lubricity of the usual bio-compatible formulations. The paper also shows that siliconisation of elastomeric contacting surface only marginally improves its tribological performance.
Description: This is an Open Access Article. It is published by Elsevier under the Creative Commons Attribution 3.0 Unported Licence (CC BY). Full details of this licence are available at: http://creativecommons.org/licenses/by/3.0
Sponsor: The authors would like to express their gratitude to the Engineering and Physical Sciences Research Council (EPSRC) for sponsorship of this research as well as 3M Health Care Ltd. for both financial and technical support.
Version: Published
DOI: 10.1016/j.apm.2012.02.035
URI: https://dspace.lboro.ac.uk/2134/13328
Publisher Link: http://dx.doi.org/10.1016/j.apm.2012.02.035
ISSN: 0307-904X
Appears in Collections:Published Articles (Mechanical, Electrical and Manufacturing Engineering)

Files associated with this item:

File Description SizeFormat
GoldOpenAccessversionAMM.pdfPublished867.73 kBAdobe PDFView/Open


SFX Query