Loughborough University
Leicestershire, UK
LE11 3TU
+44 (0)1509 263171
Loughborough University

Loughborough University Institutional Repository

Please use this identifier to cite or link to this item: https://dspace.lboro.ac.uk/2134/13512

Title: Analysis of mono-phosphate nucleotides as a potential method for quantification of DNA using high performance liquid chromatography-inductively coupled plasma-mass spectrometry
Authors: Camp, Claire L.
Sharp, Barry L.
Reid, Helen J.
Entwisle, John
Goenaga-Infante, Heidi
Keywords: Chemistry
Quantification
DNA
ICP-MS
Mass balance
Nucleotides
Issue Date: 2012
Publisher: © Springer
Citation: CAMP, C.L. ... et al, 2012. Analysis of mono-phosphate nucleotides as a potential method for quantification of DNA using high performance liquid chromatography-inductively coupled plasma-mass spectrometry. Analytical and Bioanalytical Chemistry, 402 (1), pp.367-372.
Abstract: The determination of total deoxyribonucleic acid (DNA) concentration is of great importance in many biological and bio-medical analyses. The quantification of DNA is traditionally performed by UV spectroscopy; however the results can be affected greatly by the sample matrix. The proposed method quantifies phosphorus in digested calf thymus DNA and human DNA by high performance liquid chromatography (HPLC) coupled to inductively coupled plasma mass spectrometry (ICP-MS). The method presented showed excellent baseline separation between all 4 DNA mono-nucleotides and 5’UMP. Column recoveries ranging from 95% to 99% for phosphorus resulted in a mass balance of 95% ± 0.5% for standard nucleotides, determined by LC-ICP-MS, compared to total DNA determined by flow injection coupled to ICP-MS (FI-ICP-MS). The ability of LC-ICPMS to act as an internal check that only DNA derived phosphorus was counted in the assay was demonstrated by establishing a mass balance between the total phosphorous signal from undigested DNA and that from the speciated DNA. The method for quantification was evaluated by analysis of NIST SRM 2372; a total speciated DNA recovery of 52.1 ng/μL, compared with an expected value of 53.6 ng/μL, was determined by external calibration. From repeat measurements a mass balance of 97% ± 0.5% for NIST DNA was achieved. The method limits of detection for individual nucleotides were determined between 0.8 to 1.7 μg L-1 (31P) for individual nucleotides by LC-ICP-MS, and 360 ng L-1 for 5’AMP by direct nebulisation.
Description: The final publication is available at link.springer.com.
Version: Accepted for publication
DOI: 10.1007/s00216-011-5347-y
URI: https://dspace.lboro.ac.uk/2134/13512
Publisher Link: http://dx.doi.org/10.1007/s00216-011-5347-y
ISSN: 1618-2642
Appears in Collections:Published Articles (Chemistry)

Files associated with this item:

File Description SizeFormat
DNA quant-author manuscript.pdfAccepted version211.27 kBAdobe PDFView/Open

 

SFX Query

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.