Loughborough University
Leicestershire, UK
LE11 3TU
+44 (0)1509 263171
Loughborough University

Loughborough University Institutional Repository

Please use this identifier to cite or link to this item: https://dspace.lboro.ac.uk/2134/13739

Title: Thermal and tactile interactions in the perception of local skin wetness at rest and during exercise in thermo-neutral and warm environments
Authors: Filingeri, Davide
Redortier, Bernard
Hodder, S.G.
Havenith, George
Keywords: HP
High pressure
LP
Low pressure
Mechano-receptors
Perception
Sensory integration
Skin temperature
Skin wetness
T(sk)
Thermo-receptors
Variation in local skin temperature
ΔT(sk)
Issue Date: 2013
Publisher: © Elsevier
Citation: FILINGERI, D. ... et al, 2013. Thermal and tactile interactions in the perception of local skin wetness at rest and during exercise in thermo-neutral and warm environments. Neuroscience, in press.
Abstract: The central integration of thermal (i.e. cold) and mechanical (i.e. pressure) sensory afferents is suggested as to underpin the perception of skin wetness. However, the role of temperature and mechanical inputs, and their interaction, is still unclear. Also, it is unknown whether this intra-sensory interaction changes according to the activity performed or the environmental conditions. Hence, we investigated the role of peripheral cold afferents, and their interaction with tactile afferents, in the perception of local skin wetness during rest and exercise in thermo-neutral and warm environments. Six cold-dry stimuli, characterised by decreasing temperatures [i.e. -4, -8 and -15°C below the local skin temperature (Tsk)] and by different mechanical pressures [i.e. low pressure (LP): 7 kPa; high pressure (HP): 10 kPa], were applied on the back of 8 female participants (age 21 ± 1 years), while they were resting or cycling in 22 or 33°C ambient temperature. Mean and local Tsk, thermal and wetness perceptions were recorded during the tests. Cold-dry stimuli produced drops in Tsk with cooling rates in a range of 0.06 to 0.4°C/s. Colder stimuli resulted in increasing coldness and in stimuli being significantly more often perceived as wet, particularly when producing skin cooling rates of 0.18°C/s and 0.35°C/s. However, when stimuli were applied with HP, local wetness perceptions were significantly attenuated. Wetter perceptions were recorded during exercise in the warm environment. We conclude that thermal inputs from peripheral cutaneous afferents are critical in characterizing the perception of local skin wetness. However, the role of these inputs might be modulated by an intra-sensory interaction with the tactile afferents. These findings indicate that human sensory integration is remarkably multimodal.
Description: This is the author’s version of a work that was accepted for publication in Neuroscience. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published at: http://dx.doi.org/10.1016/j.neuroscience.2013.11.019
Version: Accepted for publication
DOI: 10.1016/j.neuroscience.2013.11.019
URI: https://dspace.lboro.ac.uk/2134/13739
Publisher Link: http://dx.doi.org/10.1016/j.neuroscience.2013.11.019
Appears in Collections:Published Articles (Design School)

Files associated with this item:

File Description SizeFormat
1-s2.0-S0306452213009597-main.pdfAccepted version992.88 kBAdobe PDFView/Open

 

SFX Query

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.