Title: Measurement of circulating 25-hydroxy vitamin D using three commercial enzyme linked immunosorbent assay kits with comparison to liquid chromatography - tandem mass spectrometry method.
Authors: He, Cheng-Shiun
Gleeson, Michael
Fraser, William D.
Issue Date: 2013
Publisher: Hindawi Publishing Corporation / © Cheng-Shiun He et al.
Citation: HE, C-S., GLEESON, M. and FRASER, W.D., 2013. Measurement of circulating 25-hydroxy vitamin D using three commercial enzyme linked immunosorbent assay kits with comparison to liquid chromatography - tandem mass spectrometry method. ISRN Nutrition, 2013, Article ID 723139.
Abstract: The purpose of this study was to compare the accuracy and clinical implications of three commercial enzyme-linked immunosorbent assay (ELISA) kits (Eagle Biosciences, Immundiagnostik, and MicroVue) with a validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the measurement of serum 25(OH)D concentration. Methods. Blood samples were obtained from 225 healthy individuals who were recruited as subjects from Loughborough University, UK. Plasma samples were measured for 25(OH)D concentration by means of LC-MS/MS and ELISA kits from Eagle Biosciences, Immundiagnostik, and MicroVue. Results. The 25(OH)D concentration measured by the Eagle Biosciences, Immundiagnostik, and MicroVue ELISAs biased −50.9 ± 79.1 nmol/L, −14.2 ± 91.0 nmol/L, and −7.2 ± 18.9 nmol/L (bias ± SD) from the LC-MS/MS method, respectively. We found that 52% (Eagle Biosciences), 48% (Immundiagnostik), and 38% (MicroVue) of participants were misclassified, and the results showed the poor agreement (Kappa: −0.201~0.251) in classification of participants defined as vitamin D sufficiency and insufficiency between each method and LC-MS/MS. Conclusions. The present study demonstrated that there were negative biases and considerable misclassification of participants using the cut-off point (50 nmol/L) for vitamin D insufficiency and sufficiency using the Eagle Biosciences, Immundiagnostik, and MicroVue ELISAs compared with the LC-MS/MS assay.
Description: This article was published in the journal ISRN Nutrition, it is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Version: Published
DOI: 10.5402/2013/723139
URI: https://dspace.lboro.ac.uk/2134/13917
Publisher Link: http://dx.doi.org/10.5402/2013/723139
ISSN: 2314-4068
Appears in Collections:Published Articles (Sport, Exercise and Health Sciences)

Files associated with this item:

File Description SizeFormat
He et al 2013 ISRN Nutrition.pdf1.47 MBAdobe PDFView/Open

 

SFX Query

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.