Title: Assessment of reproducibility of thigh marker ranking during walking and landing tasks
Authors: Monnet, Tony
Thouze, Arsene
Pain, Matthew T.G.
Begon, Mickael
Keywords: Biomechanics
Movement analysis
Ranking procedure
Soft tissue artefact
Thigh kinematics
Issue Date: 2012
Publisher: Elsevier / © IPEM
Citation: MONNET, T. ... et al, 2012. Assessment of reproducibility of thigh marker ranking during walking and landing tasks. Medical Engineering and Physics, 34 (8), pp. 1200 - 1208.
Abstract: The aim of this paper is to analyse the repeatability of marker deformation and marker ranking across subjects and motor tasks. A method based on the solidification of the thigh with optimized rototranslation was applied which used 26 markers placed on the left thigh. During five trials of landing and five trials of walking for eight participants, the deformation between the actual positions of the 26 markers and the recalled positions from solidification were calculated. Markers were then sorted and ranked from the most deformed to the least deformed. Like previous studies, marker deformation found in this paper is subject and movement-dependant. The reproducibility of the marker rankings was assessed using Kendall's coefficient of concordance. Results highlighted that the marker ranking was similar between the trials of landing and between the trials of walking. Moreover, for walking and landing the rankings were consistent across the eight subjects. © 2012 IPEM.
Description: NOTICE: this is the author’s version of a work that was accepted for publication in Medical Engineering and Physics. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Medical Engineering and Physics, vol 34, issue 8, 2012 DOI: 10.1016/j.medengphy.2012.05.006
Version: Accepted for publication
DOI: 10.1016/j.medengphy.2012.05.006
URI: https://dspace.lboro.ac.uk/2134/16689
Publisher Link: http://dx.doi.org/10.1016/j.medengphy.2012.05.006
ISSN: 1350-4533
Appears in Collections:Published Articles (Sport, Exercise and Health Sciences)

Files associated with this item:

File Description SizeFormat
assess repo combo for repository.pdfAccepted version1.92 MBAdobe PDFView/Open


SFX Query

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.