Title: Performance differences across the Atlantic when UK and USA radiologists read the same set of test screening cases
Authors: Chen, Yan
Gale, Alastair G.
Evanoff, Michael
Keywords: Breast screening
FFDM
Performance
Issue Date: 2012
Publisher: © Society of Photo-Optical Instrumentation Engineers (SPIE)
Citation: CHEN, Y., GALE, A.G. and EVANOFF, M., 2012. Performance differences across the Atlantic when UK and USA radiologists read the same set of test screening cases. IN: Proc. SPIE 8318, Medical Imaging 2012: Image Perception, Observer Performance, and Technology Assessment, 831811 (February 20, 2012); doi:10.1117/12.913609
Abstract: Two groups of experienced radiologists from the UK and the USA read the same set of 40 recent FFDM screening cases to examine the effects of mammography experience, volume of cases read per year, screening practice and monitor resolution on performance,. Sixteen American radiologists reported these cases using twin DICOM calibrated monitors which were half the resolution of the clinical mammographic workstations used by 16 UK radiologists. In terms of effects of volume of cases read per year, then when the group of American radiologists were split into high and low volume readers (using 5,000 cases p.a. as a criterion) no difference in any performance measure was found. This may be partly explained by the fact that they were all were very experienced which may have counteracted any case volume effect here. Comparing the two groups of radiologists from both countries, then the UK group performed better in terms of the number of cancers detected although the American group recalled more cases, despite having poorer monitors. This reflects differences in clinical screening practice between the countries, however differences simply due to the reporting monitors used cannot be ruled out. Data from the study were also compared to that from all UK screeners who had read these cases as either soft copy or as mammographic film.
Description: Copyright 2012 Society of Photo-Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited.
Sponsor: This work is partly supported by the UK National Health Service Breast Screening Programme.
Version: Published
DOI: 10.1117/12.913609
URI: https://dspace.lboro.ac.uk/2134/20209
Publisher Link: http://dx.doi.org/10.1117/12.913609
ISSN: 0277-786X
Appears in Collections:Conference Papers and Presentations (Computer Science)

Files associated with this item:

File Description SizeFormat
831811 Performance differences across the Atlantic.pdfPublished version201.73 kBAdobe PDFView/Open

 

SFX Query

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.