Loughborough University
Leicestershire, UK
LE11 3TU
+44 (0)1509 263171
Loughborough University

Loughborough University Institutional Repository

Please use this identifier to cite or link to this item: https://dspace.lboro.ac.uk/2134/21188

Title: Effect of medial arch-heel support in inserts on reducing ankle eversion: a biomechanics study
Authors: Fong, Daniel Tik-Pui
Lam, Mak-Ham
Lao, Miko L.M.
Chan, Chad W.N.
Yung, Patrick Shu-Hang
Fung, Kwai-Yau
Lui, Po-Yee Pauline
Chan, Kai-Ming
Keywords: Running
Issue Date: 2008
Publisher: BioMed Central (© the authors)
Citation: FONG, D. ... et al., 2008. Effect of medial arch-heel support in inserts on reducing ankle eversion: a biomechanics study. Journal of Orthopaedic Surgery and Research, DOI: 10.1186/1749-799X-3-7.
Abstract: Background. Excessive pronation (or eversion) at ankle joint in heel-toe running correlated with lower extremity overuse injuries. Orthotics and inserts are often prescribed to limit the pronation range to tackle the problem. Previous studies revealed that the effect is product-specific. This study investigated the effect of medial arch-heel support in inserts on reducing ankle eversion in standing, walking and running. Methods. Thirteen pronators and 13 normal subjects participated in standing, walking and running trials in each of the following conditions: (1) barefoot, and shod condition with insert with (2) no, (3) low, (4) medium, and (5) high medial arch-heel support. Motions were captured and processed by an eight-camera motion capture system. Maximum ankle eversion was calculated by incorporating the raw coordinates of 15 anatomical positions to a self-compiled Matlab program with kinematics equations. Analysis of variance with repeated measures with post-hoc Tukey pairwise comparisons was performed on the data among the five walking conditions and the five running conditions separately. Results. Results showed that the inserts with medial arch-heel support were effective in dynamics trials but not static trials. In walking, they successfully reduced the maximum eversion by 2.1 degrees in normal subjects and by 2.5-3.0 degrees in pronators. In running, the insert with low medial arch support significantly reduced maximum eversion angle by 3.6 and 3.1 degrees in normal subjects and pronators respectively. Conclusion. Medial arch-heel support in inserts is effective in reducing ankle eversion in walking and running, but not in standing. In walking, there is a trend to bring the over-pronated feet of the pronators back to the normal eversion range. In running, it shows an effect to restore normal eversion range in 84% of the pronators.
Version: Published
DOI: 10.1186/1749-799X-3-7
URI: https://dspace.lboro.ac.uk/2134/21188
Publisher Link: http://dx.doi.org/10.1186/1749-799X-3-7
ISSN: 1749-799X
Appears in Collections:Published Articles (Sport, Exercise and Health Sciences)

Files associated with this item:

File Description SizeFormat
Effect of medial arch-heel support in inserts on reducing ankle eversion: a biomechanics study.pdfPublished version942.35 kBAdobe PDFView/Open


SFX Query

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.