Loughborough University
Leicestershire, UK
LE11 3TU
+44 (0)1509 263171
Loughborough University

Loughborough University Institutional Repository

Please use this identifier to cite or link to this item: https://dspace.lboro.ac.uk/2134/21293

Title: A high performance biometric signal and image processing method to reveal blood perfusion towards 3D oxygen saturation mapping
Authors: Imms, Ryan
Hu, Sijung
Azorin-Peris, Vicente
Trico, Michael
Summers, Ron
Keywords: Imaging photoplethysmography
Pulse oximetry
Oxygen saturation mapping
Signal acquisition and processing
Issue Date: 2014
Publisher: © Society of Photo-Optical Instrumentation Engineers
Citation: IMMS, R. ... et al., 2014. A high performance biometric signal and image processing method to reveal blood perfusion towards 3D oxygen saturation mapping. Proceedings of SPIE, 8947, DOI: 10.1117/12.2044318.
Abstract: Non-contact imaging photoplethysmography (PPG) is a recent development in the field of physiological data acquisition, currently undergoing a large amount of research to characterize and define the range of its capabilities. Contact-based PPG techniques have been broadly used in clinical scenarios for a number of years to obtain direct information about the degree of oxygen saturation for patients. With the advent of imaging techniques, there is strong potential to enable access to additional information such as multi-dimensional blood perfusion and saturation mapping. The further development of effective opto-physiological monitoring techniques is dependent upon novel modelling techniques coupled with improved sensor design and effective signal processing methodologies. The biometric signal and imaging processing platform (bSIPP) provides a comprehensive set of features for extraction and analysis of recorded iPPG data, enabling direct comparison with other biomedical diagnostic tools such as ECG and EEG. Additionally, utilizing information about the nature of tissue structure has enabled the generation of an engineering model describing the behaviour of light during its travel through the biological tissue. This enables the estimation of the relative oxygen saturation and blood perfusion in different layers of the tissue to be calculated, which has the potential to be a useful diagnostic tool.
Description: © 2014 Society of Photo Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited.
Sponsor: The authors would like to thank the financial support of Loughborough University and the RCLEDs supplier WelTek Co. Ltd., Taiwan.
Version: Published
DOI: 10.1117/12.2044318
URI: https://dspace.lboro.ac.uk/2134/21293
Publisher Link: http://dx.doi.org/10.1117/12.2044318
ISSN: 0277-786X
Appears in Collections:Published Articles (Mechanical, Electrical and Manufacturing Engineering)

Files associated with this item:

File Description SizeFormat
A high performance biometric signal and image processing method to.pdfPublished version835.73 kBAdobe PDFView/Open

 

SFX Query

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.