Title: Nitrogen species measurement investigation using two different FTIR
Authors: Li, Nilton
El-Hamalawi, Ashraf
Barrett, Richard
Wheatley, Andrew D.
Robinson, Jonathan
Keywords: Ammonia
Diesel engine emission
Issue Date: 2016
Publisher: International Academy of Science, Technology, Engineering and Management
Citation: Li, N. ...et al., 2016. Nitrogen species measurement investigation using two different FTIR. Presented at the 18th IASTEM International Conference, Berlin, Germany, 29 th March, pp. 24-29.
Abstract: Current diesel engine after-treatment systems, such as Selective Catalyst Reduction (SCR), use ammonia (NH3) to reduce the Oxides of Nitrogen (NOx) into Nitrogen (N2) and water; however, if the reaction between ammonia and NOx unbalance this can lead either ammonia or NOx being released into the environment. Ammonia is classified as dangerous compound for the environment; therefore, accurate measurement of ammonia is essential. Fourier Transform Infrared (FTIR) is one of the most common method used to measure raw emissions from engine exhaust pipes, due to its capability to measure multi-type emissions at the same time. However, not many FTIRs that can measure gas from engine exhaust, and most of them has different characteristics and specifications. These can affect the emission measurement from exhaust pipes and lead to uncertainties in meeting compliance demands. The work of this paper compares two FTIR that have different specifications. These FTIRs, have been compared under well controlled laboratory conditions. The concentration of ammonia and NOx from diesel engines has been measured under different engine load and speed. The ammonia readings from each FTIR are plotted into a graph and analysed, the results show that one of the FTIR produces a lower reading compare to the other FTIR. A Chemical Luminance Detector (CLD) was used to measure the NOx and then compared with both FTIRs. After analysed those dataset, the results clearly show the FTIR specification can affect the emission measurement from diesel engines exhaust.
Description: This is a conference paper.
Version: Published
URI: https://dspace.lboro.ac.uk/2134/22233
Publisher Link: http://www.worldresearchlibrary.org/up_proc/pdf/216-145924972824-29.pdf
ISBN: 9789385973857
Appears in Collections:Conference Papers (Civil and Building Engineering)

Files associated with this item:

File Description SizeFormat
NITROGEN_SPECIES_MEASUREMENT.pdfPublished version767.84 kBAdobe PDFView/Open


SFX Query

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.