Title: Finger skin cooling on contact with cold materials: an investigation of male and female responses during short-term exposures with a view on hand and finger size
Authors: Havenith, George
Keywords: Cold injury
Skin freezing
Hand size
Gender differences
Issue Date: 2006
Publisher: © Springer-Verlag
Citation: JAY, O. and HAVENITH, G., 2004. Finger skin cooling on contact with cold materials: a comparison between male and female responses during short-term exposures. European Journal of Applied Physiology, 91(4), pp. 373-381
Abstract: This study investigates the independent effects of hand anthropometry and gender upon contact cooling responses. Subjects were selected for matching hand/finger size between genders, with equal variation between individuals of each group. Fourteen volunteers (7 male, 7 female) participated, touching blocks of aluminium and stainless steel using the first phalanx of the index finger with a contact force of 1.0N and 9.8N, at surface temperatures of –2°C and – 10°C. Conditions were selected in order to elicit varying rates of skin cooling upon contact. Contact temperature (TC) of the finger-pad was measured over time using a T-type thermocouple. Overall, no significant difference was found between the cooling responses of males and females. In order to investigate whether differences in hand anthropometry correlated with contact cooling response, a multiple regression approach was used. Analyses of the residual variance in contact cooling data after the effects of material type, surface temperature and finger contact force had been accounted for, showed that, under slow cooling conditions (over 45 seconds to reach TC = 1°C), hand size correlated significantly with contact cooling response only when represented by index finger volume (p<0.05), and gender did not. Whilst under fast cooling conditions (below 25 seconds to reach TC = 1°C), hand size did not correlate significantly with contact cooling response at all, but gender had a significant effect (p<0.001). Under slow cooling conditions, a larger finger (and most cases hands) provides a higher heat content thus giving a slower skin cooling speed. Under fast cooling conditions, the significantly longer time required for males to reach a TC of 1°C despite matching hand and finger size is attributed to higher epidermal insulation provided by the thicker stratum corneum typically found in males, combined with the higher starting skin temperature observed in the “slightly cool” environment.
Description: This is a pre-print. The definitive version: JAY and HAVENITH (2004) Finger skin cooling on contact with cold materials: a comparison between male and female responses during short-term exposures. European Journal of Applied Physiology, 91(4), pp. 373-381 is available at: springerlink.metapress.com/openurl.asp?genre=journal&issn=1439-6319.
Version: Submitted for publication
DOI: 10.1007/s00421-003-0986-0
URI: https://dspace.lboro.ac.uk/2134/2563
Publisher Link: http://www.springerlink.com/content/1439-6319/
ISSN: 1439-6319
1439-6327