Title: Single-sided natural ventilation strategies for healthcare buildings
Authors: Adamu, Zulfikar A.
Price, Andrew D.F.
Cook, Malcolm J.
Issue Date: 2011
Publisher: Tapir Akademisk
Citation: ADAMU, Z., PRICE, A. and COOK, M., 2011. Single-sided natural ventilation strategies for healthcare buildings. IN: Proceedings of 2011 12th International Conference on Air Distribution in Rooms (RoomVent 2011), Trondheim, Norway, 19-22 June 2011, paper no. 134.
Abstract: Control of airborne pathogens, while achieving comfort and energy efficiency, places strains on typical mechanical air-conditioning systems of hospitals. These buildings expend over 40% of their energy for heating of air and spaces (DoH, 2006) while still being challenged by the problem of airborne infection. Natural ventilation remains a largely unexplored alternative which could alleviate this problem; however, achieving acceptable indoor air quality (IAQ), thermal comfort and energy efficiency from this technique is challenging and requires careful design and modelling. Many hospitals appear to use same openings (windows) as both inlets and outlets, making the air exchange process inefficient. The aim of this study is therefore, to demonstrate the feasibility of using dual opening single-sided, buoyancy-driven natural ventilation for achieving low-energy comfort and reduction of airborne pathogens in 1-bed and 4-bed hospital wards that are designed or refurbished according to the Department of Health’s Activity Database (ADB). Conceptual design conditions were based on provisions of HTM-03 guidelines and openings were sized through empirical methods. The design conditions are tested using dynamic thermal simulation (DTS) to demonstrate the long-term airflow and comfort implications. Computational fluid dynamics simulations (CFD) are then used to provide an indepth steady-state prediction of the distribution and quality of air as well as pathogen dispersal, with respect to airflow patterns/directions for the selected strategies. These research findings provide insights into the airflow, and comfort performances of 1-bed and 4-bed wards for both existing and proposed healthcare buildings whose design or retrofit calls for single-sided natural ventilation.
Sponsor: The authors are grateful to Health and Care Infrastructure Research and Innovation Centre (HaCIRIC) and ESPRC for supporting this research.
Version: Accepted for publication
URI: https://dspace.lboro.ac.uk/2134/26727
Publisher Link: https://www.fagbokforlaget.no/
ISBN: 8251928125
9788251928120
Appears in Collections:Closed Access (Architecture, Building and Civil Engineering)

Files associated with this item:

File Description SizeFormat
26727.pdf1.42 MBAdobe PDFView/Open

 

SFX Query

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.