Loughborough University
Leicestershire, UK
LE11 3TU
+44 (0)1509 263171
Loughborough University

Loughborough University Institutional Repository

Please use this identifier to cite or link to this item: https://dspace.lboro.ac.uk/2134/3129

Title: An application of computational fluid dynamics (CFD) to the characterisation and optimisation of a cyclonic spray chamber for CP-AES
Authors: Schaldach, Gerhard
Berndt, Harald
Sharp, Barry L.
Issue Date: 2003
Publisher: © RSC Publishing
Citation: SCHALDACH, G., BERNDT, H. and SHARP, B.L., 2003. An application of computational fluid dynamics (CFD) to the characterisation and optimisation of a cyclonic spray chamber for CP-AES. Journal of analytical atomic spectrometry, 18, pp. 742–750
Abstract: This paper describes the application of computational fluid dynamics (CFD) to the modelling of the performance of a cyclonic spray chamber with flow spoiler designed to provide good efficiency with rapid wash-out time. The modelling is carried out under two flow regimes, one corresponding to typical sample introduction conditions and one to low sample uptake. Velocity distributions, pressure distributions and mass flows are simulated, the latter employing the measured primary aerosol distributions as inputs to the computation. The dynamic performance of chambers is also modelled and the signal profiles produced are shown to correspond to those derived directly from measurement. Six different chambers are studied corresponding to a chamber with no spoiler, a single spoiler in four different positions, and a chamber with 3 spoilers. The position of the spoiler is shown to be critical in determining the flow field in the chamber and hence the efficiency and washout time. It is demonstrated that chamber geometry has maximum impact under low uptake conditions where the limited dispersion primary aerosol can effectively follow the gas flow lines. Computation indicates that a chamber with optimised spoiler, operating under low uptake conditions, provides the best combination of efficiency and response time. This was confirmed by experiment in which the performance of 3 different chambers was compared, with the optimised design providing detection limits 1.5– 19 better than those obtained with the chamber supplied with the ICP-AES instrument. A chamber with 3 spoilers indicates the formation of a low-volume
Description: This article is Restricted Access. It was published in the journal, Journal of analytical atomic spectrometry [© RSC Publishing] and is available at: http://www.rsc.org/jaas
URI: https://dspace.lboro.ac.uk/2134/3129
ISSN: 0267-9477
Appears in Collections:Closed Access (Chemistry)

Files associated with this item:

File Description SizeFormat
Cyclone-CFD.pdf617.05 kBAdobe PDFView/Open

 

SFX Query

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.