Title: The hardened performance of wet process sprayed mortars [Published title: The performance of hardened wet-process sprayed mortars]
Authors: Austin, Simon A.
Robins, Peter J.
Goodier, Chris I.
Issue Date: 2000
Publisher: © Thomas Telford
Citation: AUSTIN, S.A., ROBINS, P.J. and GOODIER, C.I., 2000. The performance of hardened wet-process sprayed mortars. Magazine of Concrete Research, 52(3), pp. 195–208.
Abstract: This paper, which reports on part of a three year research project into wet-process sprayed mortars and concretes for repair, investigates the hardened performance of wet process sprayed mortars. Seven commercially available pre-packaged repair mortars were pumped and sprayed through a worm pump, three through a piston pump and two through a dry spray machine. A laboratory designed mortar was also worm and piston pumped. The properties measured included compressive and flexural strength, tensile bond strength, hardened density, modulus of elasticity, air permeability, sorptivity and drying and restrained shrinkage. In-situ test specimens were extracted from 500mmx500mmx100mm deep sprayed panels. Tests were also conducted on corresponding cast specimens and, where possible, on specimens that had been sprayed directly into a cube or beam mould. A new test to quantify the degree of reinforcement encasement has been developed and an initial investigation into the measurement of the restrained shrinkage of in-situ repairs is presented. The compressive and flexural strengths of the laboratory mix were comparable with the best of the commercially available preblended mortars. The values for modulus of elasticity, when compared with the compressive strength, were lower than published formulas for this relationship would suggest, especially at lower strengths. The air permeability of most of the mortars was lower than that for normal wet-cured concrete and decreased with an increase in compressive strength. The sorptivity values showed no clear relationship with the compressive strength. The type of wet-process pump was found to have little effect on the insitu compressive and flexural strengths, but did affect the bond strength, although mainly due to the stream velocity and w/c ratio rather than the pumping process. The pump type also effected the reinforcement encasement with higher stream velocities producing better encasement. The mixes exhibited a wide range of drying shrinkage, but the data from the restrained specimens suggest an actual repair is influenced as much by ambient conditions as it is by the mix proportions.
Description: This article was published in the journal, Magazine of Concrete Research [© Thomas Telford] and the definitive version is available at: http://www.thomastelford.com/journals/
Version: Accepted for publication
URI: https://dspace.lboro.ac.uk/2134/5169
ISSN: 0024-9831
Appears in Collections:Published Articles (Civil and Building Engineering)