Loughborough University
Leicestershire, UK
LE11 3TU
+44 (0)1509 263171
Loughborough University

Loughborough University Institutional Repository

Please use this identifier to cite or link to this item: https://dspace.lboro.ac.uk/2134/5722

Title: Modelling crossflow electro- and micro-filtrations
Authors: Wakeman, Richard J.
Tarleton, E.S.
Issue Date: 1986
Publisher: World Filtration Congress; Koninklijke Vlaamse Ingenieursvereniging; Section on Mechanical Separation and Particle Technology; Filtration Society (Great Britain); Flemish Chapter.
Citation: WAKEMAN, R.J. and TARLETON, E.S., 1986. Modelling crossflow electro- and micro- filtrations. IN: Vanbrabant, R., Hermia, J. and Weiler, R.A. (eds.). 4th World Filtration Congress, Proceedings, Technologisch Instituut-Koninklijke Vlaamse Ingenierusvereniging, Ostend, Belgium, pp.11.1-11.10.
Abstract: Experimental data from a tubular crossflow filter, operated with and without imposed d.c. electric fields, are presented. The drop-off of filtrate rate as the membrane fouls has been monitored for a variety of operating conditions. A simple mathematical model has been developed to interpret the experimental results; the model facilitates particle trajectory (and hence membrane fouling) calculations from a knowledge of the particle properties and suspension flow parameters.
Description: This is a conference paper.
Version: Not specified
URI: https://dspace.lboro.ac.uk/2134/5722
Appears in Collections:Conference Papers and Presentations (Chemical Engineering)

Files associated with this item:

File Description SizeFormat
Electric field WFC4 1986 repository.pdf374.96 kBAdobe PDFView/Open

 

SFX Query

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.