Loughborough University
Leicestershire, UK
LE11 3TU
+44 (0)1509 263171
Loughborough University

Loughborough University Institutional Repository

Please use this identifier to cite or link to this item: https://dspace.lboro.ac.uk/2134/6052

Title: The margin for error when releasing the asymmetric bars for dismounts
Authors: Hiley, Michael J.
Yeadon, Maurice R.
Keywords: Gymnastics
Simulation
Release window
Angular momentum
Issue Date: 2005
Publisher: © Human Kinetics, Inc.
Citation: HILEY, M.J. and YEADON, M.R., 2005. The margin for error when releasing the asymmetric bars for dismounts. Journal of Applied Biomechanics, 21 (3), pp.223-235.
Abstract: It has previously been shown that male gymnasts using the “scooped” giant circling technique were able to flatten the path followed by their mass centre resulting in a larger margin for error when releasing the high bar (Hiley and Yeadon, 2003a). The circling technique prior to performing double layout somersault dismounts from the asymmetric bars in Women’s Artistic Gymnastics appears to be similar to the “traditional” technique used by some male gymnasts on the high bar. It was speculated that as a result the female gymnasts would have margins for error similar to those of male gymnasts who use the traditional technique. However, it is unclear how the technique of the female gymnasts is affected by the need to avoid the lower bar. A four segment planar simulation model of the gymnast and upper bar was used to determine the margins for error when releasing the bar for nine double layout somersault dismounts at the Sydney 2000 Olympic Games. The elastic properties of the gymnast and bar were modelled using damped linear springs. Model parameters, primarily the inertia and spring parameters, were optimised to obtain a close match between simulated and actual performances in terms of rotation angle (1.2°), bar displacement (0.011 m) and release velocities (< 1%). Each matching simulation was used to determine the time window around the actual point of release for which the model had appropriate release parameters to complete the dismount successfully. The margins for error of the nine female gymnasts (release window 43 - 102 ms) were comparable with those of the three male gymnasts using the traditional technique (release window 79 - 84 ms).
Description: This article was accepted for publication in the Journal of Applied Biomechanics [© Human Kinetics, Inc.] and the definitive version is at: http://hk.humankinetics.com/JAB/toc.cfm?iss=643
Version: Accepted for publication
URI: https://dspace.lboro.ac.uk/2134/6052
ISSN: 1065-8483
1543-2688
Appears in Collections:Published Articles (Sport, Exercise and Health Sciences)

Files associated with this item:

File Description SizeFormat
hiley2005b.pdf181.2 kBAdobe PDFView/Open

 

SFX Query

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.