Title: Sampling and characterisation of volatile organic compound profiles in human saliva using a polydimethylsiloxane coupon placed within the oral cavity
Authors: Martin, Helen J.
Riazanskaia, Svetlana
Thomas, C.L.P.
Keywords: Gas chromatography
Mass spectrometry
Human saliva
Volatile organic compounds
Solid phase extraction
Thermal desorption
Issue Date: 2012
Publisher: RSC Publishing (© H.J. Martin, S. Riazanskaia and C.L.P. Thomas)
Citation: MARTIN, H.J., RIAZANSKAIA, S. and THOMAS, C.L.P., 2012. Sampling and characterisation of volatile organic compound profiles in human saliva using a polydimethylsiloxane coupon placed within the oral cavity. Analyst, 137, pp. 3627–3634.
Abstract: Evaluation of published methods reveals that existing methods for saliva sampling do not address the physical chemical attributes of volatile organic compounds (VOC). This study describes and presents evidence for adopting in-situ sampling of salivary VOC directly from the oral cavity using a polydimethylsiloxane (PDMS) based sampler. In-vitro studies indicated that the vapour pressure of analytes was a factor in both the recovery of analytes, and in the precision of the recovery. The highest recoveries were observed for VOC with the lowest vapour pressures, for example 5-nonanol (vapour pressure (Pv) = 14 PA) recoveries were approximately 20-times greater than those observed for octane (Pv = 1726 PA). Similarly, relative standard deviations reduced with vapour pressure, with the RSD for 5-nonanol responses observed to be 2.7 % to compared to RSD = 26 % for octane. Evaluation of VOC recovered from 6 in-vivo samples indicated that VOC concentrations in saliva may follow lognormal distributions; log-normal RSDs falling between 4.4% to 18.2% across the range of volatilities encountered. Increasing sampling time from 1 to 30 minutes indicated that the recovery of VOC into the sampler was effected by interaction between different physical chemical properties and biogenic flux. A sampling time of 10 min was found to offer an acceptable compromise that enabled a representative sample to be acquired for the widest range of observed VOC behaviours with the sampler. The potential to ‘tune’ the sampling protocol for targeted analysis based on these factors was also noted. Comparison with passive drool saliva collection revealed up to 105 enhancment with reduced variability compared to drooled samples. This approach to in-situ saliva sampling appears to have significant analytical utility for studying volatile signatures in humans.
Description: This article was published in the journal, Analyst [RSC Publishing] and the definitive version is available at: http://dx.doi.org/10.1039/C2AN35432B
Version: Accepted for publication
DOI: 10.1039/C2AN35432B
URI: https://dspace.lboro.ac.uk/2134/9894
Publisher Link: http://dx.doi.org/10.1039/C2AN35432B
http://pubs.rsc.org/en/journals/journalissues/an
ISSN: 0003-2654
Appears in Collections:Published Articles (Chemistry)

Files associated with this item:

File Description SizeFormat
AN-ART-03-2012-035432.pdf1.01 MBAdobe PDFView/Open

 

SFX Query

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.